The Dual Natural Ventilation Control (NVC-DUAL) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The NVC-DUAL automatically controls the temperature in a room by operating two curtain machines or actuators according to your programmed settings.

Controlling a curtain machine

  • When the temperature is within the idle band of the set point, the NVC-DUAL maintains the curtain position.
  • When the temperature rises above the Idle band, the NVC-DUAL opens the curtain for the on duration, and then pauses for the off duration.
  • After each Off duration, the NVC-DUAL checks the temperature and then either opens or closes the curtain (for the preset duration), depending on the temperature.

Optional rain override

The optional Phason Rain Sensor allows the NVC-DUAL to override normal operation when it is raining. When rainfall is detected, the control closes the configured curtains/actuators. After 15 minutes with no detected rainfall, the control resumes normal operation.

Other models

  • NVC-2
  • NVC-2-12
  • NVC-2-24

– MORE –

PRODUCTS

Description

Effective control of two curtain machines

The Dual Natural Ventilation Control (NVC-DUAL) is a fully programmable controller that provides extensive flexibility for your curtain or awning control needs. The NVC-DUAL automatically controls the temperature in a room by operating two curtain machines or actuators according to your programmed settings.

Controlling a curtain machine

  • When the temperature is within the idle band of the set point, the NVC-DUAL maintains the curtain position.
  • When the temperature rises above the Idle band, the NVC-DUAL opens the curtain for the on duration, and then pauses for the off duration.
  • After each Off duration, the NVC-DUAL checks the temperature and then either opens or closes the curtain (for the preset duration), depending on the temperature.

Optional rain override

The optional Phason Rain Sensor allows the NVC-DUAL to override normal operation when it is raining. When rainfall is detected, the control closes the configured curtains/actuators. After 15 minutes with no detected rainfall, the control resumes normal operation.